Why It Matters

The control plan is the PPAP element that commits a supplier to how every characteristic is measured, how often, and what happens when a check fails. This guide covers the 2024 AIAG changes, each column, and an annotated CNC example.

A PPAP control plan is the supplier's written plan for controlling a part's production process. For each process step it lists the product and process characteristics, the specification, the measurement method, sample size and frequency, the control method, and the reaction plan when a check fails. It is element 7 of 18 PPAP elements, signed by supplier and customer.

A customer's supplier quality engineer reads the control plan to see how the part will be held to print on every shift, not only during the sample run. Dimensional results and initial process studies describe parts already made. The control plan describes what the supplier will do for the thousands still to come, and it is the document an auditor will hold the floor to later.

Where the control plan sits in PPAP

The standard list of 18 PPAP elements puts the control plan at element 7, immediately after the process FMEA (element 6) and before measurement system analysis studies (element 8). That list describes the element as "A copy of the Control Plan, reviewed and signed off by supplier and customer." The other elements include design records, the DFMEA, the process flow diagram, dimensional results, initial process studies, customer-specific requirements (element 17) and the Part Submission Warrant (element 18).

The order is useful. The PFMEA identifies the risks, the control plan commits to the controls, and the MSA studies that follow should prove the gauges the control plan names can actually see the tolerance.

Within IATF 16949, the control plan is clause 8.5.1.1. The standard itself is paywalled, so the summaries here come from secondary sources. Advisera's summary says the control plan must include the controls used for manufacturing process control, verification of job set-ups, first-off/last-off part validation, methods for monitoring special characteristics, and a reaction plan for nonconformities or for a process that becomes unstable or not statistically capable. Both Advisera and 16949store describe Annex A as grouping the minimum content into general data, product control, process control, methods, and reaction plan.

Prototype, pre-launch and production phases

IATF 16949 recognizes three control plan phases. Advisera's summary describes the prototype plan as "a description of the dimensional measurements, material, and performance tests," which the customer may require. The pre-launch plan covers the period between prototype and full production. The production plan documents product and process characteristics, process controls, tests and measurement systems during mass production.

In the new AIAG manual, John Vandenbemden writes in Quality Magazine that the Prototype Build Control Plan belongs to the Product Design/Development phase of APQP, the Pre-Launch Control Plan belongs to Process Design/Development, and the Production Control Plan belongs to Product and Process Validation, the phase where the production process is proven out. Safe Launch, which AIAG describes as a new requirement added to the control plan phases, sits inside the pre-launch plan in Vandenbemden's account. In practice that means the extra launch controls should be written into the pre-launch document rather than kept as an informal launch checklist off to the side. Customer-specific requirements decide which phase plans a given customer wants to see, so check them before assembling the package.

Control plan vs PFMEA

The two documents are built from the same process flow but do different jobs. The PFMEA is an analysis. It asks what could go wrong at each step, why, and what prevention and detection controls exist. The control plan is an operating commitment. It takes those controls and states, characteristic by characteristic, how they will be run on the floor: with which gauge, on how many parts, how often, and what the operator does when a result is bad.

Good practice is a clean trace between them. A characteristic the PFMEA treats as high risk should appear in the control plan with the same name, the same detection method and a reaction plan, and the two documents should carry consistent revisions. When an SQE finds a detection control in the PFMEA that never shows up in the control plan, the obvious question is whether anyone is running it.

Terminology has shifted under both documents. The AIAG-VDA FMEA Handbook is dated 2019, according to Quality Digest, and Vandenbemden cites terms that changed with IATF 16949 and the VDA FMEA Handbook as one reason AIAG rewrote its control plan guidance.

Control plan vs work instructions

Work instructions fall under a separate IATF 16949 clause, 8.5.1.2, which covers standardized work, operator instructions and visual standards. They tell the operator how to do the task: load the part, touch off the tool, run the cycle. The control plan (8.5.1.1) sets what is verified, how often, and what happens when a check fails.

Plants get into trouble when one document tries to do the other's job. A control plan stuffed with step-by-step operator instructions becomes unreadable for the customer. A work instruction that quietly sets its own check frequency drifts away from what the customer signed. The cleaner approach is to reference the work instruction number in the control plan and to make sure the check the operator performs at the machine is the one the control plan specifies.

What changed in 2024

For almost three decades, control plan guidance lived in AIAG's APQP and Control Plan Second Edition Reference Manual, published in 1995, Vandenbemden notes. In March 2024 AIAG split it out. The new Control Plan 1st Edition (product code CP-1) was released alongside APQP 3rd Edition, and an AIAG blog post dated 28 March 2024 said the new editions were "Required by General Motors as of September 1, 2024."

Vandenbemden gives three reasons for the split: terminology changed with IATF 16949 and the VDA FMEA Handbook, nearly 30 years of feedback and lessons learned had accumulated, and technology moved on. On that last point he writes, "Functions identified in the Control Plan are embedded in automated systems." The manual's chapters cover requirements and guidelines, control plan development, the three phases, and effective use of control plans. Appendix A holds "Examples of Control Plans for key Process Types."

AIAG's product page lists the additions as a Safe Launch requirement in the control plan phases, examples for highly automated manufacturing, guidance on using software to develop and manage control plans, and revised examples, tables, forms and checklists.

On the form itself, Brian Martensen of Plex, a Rockwell Automation company, writes in Quality Magazine that a new "Responsible Person" column is "the only noticeable change to the control plan form." It points the team to the functional role that leads the reaction plan, which, he notes, helps avoid a reaction plan that is entirely "Notify Supervisor." The manual also covers family control plans. Martensen describes them this way: "Family control plans are used to manage common parts of different part numbers on one control plan document."

Suppliers with a drawer full of approved plans can relax somewhat. Before publication, DQS reported that "suppliers will NOT have to update existing Control Plans to meet the new requirements," and that Ford, GM and Stellantis would accept the new manuals immediately after publication. New launches and revisions are the natural point to move to the new form.

Machined parts and IATF Sanctioned Interpretation 24

Machining shops running CNC cells with tool-life management, in-process probing and MES-driven inspection plans have a specific allowance. DQS reports that IATF Sanctioned Interpretation 24, effective June 2022, added a note to Annex A.1. For highly automated processes ("e.g., semiconductors, machining, welding") where the control method, meaning the specification or tolerances, sample size and frequency, is controlled by a system such as an MES, "summary control information is acceptable with direct references or linkage to the system."

That lets a shop stop maintaining the same limits in two places, which is a common source of revision mismatches. The burden shifts to the linkage: the summary plan has to point to the exact program, inspection plan or MES record, and that system has to be under revision control. The same DQS post reports that SI 25 allows the part number field to read "part number(s)" or a "common control plan designation," which supports the family approach.

The columns, one at a time

AIAG's exact CP-1 form layout isn't reproduced here. The column set below is a common software template, taken from ReliaSoft's Xfmea documentation, and it maps closely to what most customers expect. Under each column is the point most likely to draw a question from the customer.

  • Part/Process Number. Ties each row to the process flow. If a family plan is used, the common designation must cover every part number it claims and nothing more.

  • Process Name/Operation Description. Should match the process flow diagram and PFMEA wording exactly. Different names for the same operation across the three documents make the trace hard to follow.

  • Machine, Device, Jig, Tools for Mfg. Identify the specific machine or fixture. If two lathes can run the operation, say so, because a set-up verification on one doesn't cover the other.

  • Characteristic Number. Should tie back to the ballooned drawing used for dimensional results.

  • Product Characteristic. The feature on the part: a diameter, a surface finish, a thread.

  • Process Characteristic. The variable that produces the feature: tool offset, tool life, clamp pressure, spindle load. Martensen observes that "some control plans tend to sway toward product over process." A plan with only product checks detects defects after they're made rather than controlling the inputs that cause them.

  • Special Char. Class. Use the customer's symbol. Each special characteristic needs a stated monitoring method, which is one of the required contents in the IATF summaries above.

  • Specification/Tolerance. Should match the current drawing revision. For automated processes under SI 24, a reference to the controlling system is acceptable.

  • Evaluation/Measurement Technique. Name the gauge type, and ideally the gauge ID or MSA study reference, so the link to element 8 is visible.

  • Sample Size and Sample Frequency. "As required" or "periodic" invites a question. State a number and a trigger: per hour, per lot, after every tool change.

  • Control Method. SPC chart, error-proofing device, check sheet, first-off approval. Say which one, and make sure the floor actually runs it.

  • Reaction Plan. What happens to the process and to suspect product. This is where Martensen's "Notify Supervisor" warning applies.

  • Responsibility. The functional role that owns the reaction. This is the column the new AIAG form names "Responsible Person."

  • Remarks. Work instruction references, MES links, or customer-specific notes.

Weak points that draw pushback

There's no verified data ranking which columns customer quality engineers reject most often. What is on record is Martensen's report that "control plans are consistently in the top ten of IATF major and minor non-conformances." The weak points below come from the requirements and the practitioner sources cited here, not from a statistical ranking.

Elevated view of a wire-mesh hold cage on a concrete floor containing a steel tote of machined shafts with a blank red tag, and one shaft set apart on a rack top nearby.

  • Reaction plans that only say "notify supervisor." That's an escalation, not a reaction. A usable reaction plan says to stop or adjust the process, how far back to contain suspect product, how to sort or disposition it, and who leads.

  • Product checks with process parameters left out. Martensen's "product over process" point. If tool life or offset drives the diameter, the plan should control it.

  • No job set-up verification or first-off/last-off validation. Both are listed as required contents in Advisera's summary of IATF 16949. Last-off checks matter because they confirm the run ended good, which bounds containment if something drifted.

  • Special characteristics without a monitoring method. A symbol on the drawing with a vague check frequency in the plan is an easy finding.

  • A plan that wasn't updated after a trigger event. Both Advisera and 16949store summarize IATF 16949 as requiring review and update after nonconforming product ships to the customer, after a change affecting the product or process, after a customer complaint leads to corrective action, and at a frequency set by risk analysis.

  • No named owner for the reaction. The new Responsible Person column exists for this reason.

An annotated example: CNC-machined steel shaft

This is an illustrative example written by ManufacturingMag's editors. It is not a real customer submission, and every number, gauge ID and frequency is invented to show structure. A real plan takes its tolerances from the drawing and its frequencies from the PFMEA and process capability data.

Elevated view of an idle CNC lathe cell with a freshly turned steel shaft in a foam tray beside a snap gauge and micrometer, with other machines blurred in the background.

The part is a turned-and-milled steel shaft. OP10 turns the bearing journal on a CNC lathe; OP20 mills a keyway on a vertical machining center. The phase is marked as Production.

Op / MachineChar. No.Product char.Process char.SpecialSpec / toleranceMeasurement techniqueSample / frequencyControl methodReaction planResponsible
OP10 CNC lathe L210.1All OP10 features (set-up and first-off)Program revision, tool offsets loadedPer drawing rev CCMM layout, program CMM-1141 piece after set-up, tool change or program editFirst-off approval recordDo not release cell. Correct set-up, rerun first-off.Set-up technician; quality technician approves
OP10 CNC lathe L210.2Bearing journal diameterCustomer SC symbol25.000 / 24.987 mmDigital snap gauge G-207 (GRR study MSA-207)5 pieces every hourX-bar and R chartStop machine. Quarantine all parts since last in-control subgroup, 100% sort with G-207, adjust offset, verify 5 pieces before restart, record on chart.Cell lead; quality engineer dispositions
OP10 CNC lathe L210.3Finishing insert tool life400 parts maxCNC tool-life counterEvery cycleError-proofing: counter blocks cycle start at limitChange insert, run first-off check on 10.2 before restart. If counter found bypassed, quarantine parts since last change.Machine operator; maintenance verifies counter weekly
OP10 CNC lathe L210.4Bearing journal diameter (last-off)Customer SC symbol25.000 / 24.987 mmDigital snap gauge G-207Last piece of each runLast-off record attached to lotIf out of tolerance, hold the lot and sort back to last acceptable check.Machine operator; quality technician
OP20 VMC M420.1Keyway width6.000 / 6.030 mmGo/no-go plug gauge G-3111 piece every 25Check sheetStop machine. Quarantine parts since last good check, 100% gauge, replace cutter, first-off before restart.Cell lead
OP20 VMC M420.2Fixture clamp pressureWithin set range on pressure switchPressure switch interlockEvery cycleError-proofing: no cycle start without pressureIf interlock fails or is overridden, stop machine, quarantine parts since last verified interlock check, notify maintenance.Machine operator; maintenance

A few things in the example are deliberate.

  • Row 10.1 and row 10.4 bracket the run with set-up verification and a last-off check, the two items Advisera's summary lists as required. The last-off record is what lets a plant limit containment to one run instead of a week of shipments.

  • Row 10.2 carries the customer's special characteristic symbol, a gauge with a traceable MSA study, and SPC. Its reaction plan states containment scope ("since last in-control subgroup"), the sort method, the restart condition, and the role that leads.

  • Row 10.3 is a process characteristic. The diameter in 10.2 moves with insert wear, so the plan controls the cause as well as the result. It also says what to do if the error-proofing itself is defeated, which is the case a reviewer will ask about.

  • Row 20.2 controls clamp pressure, an input to the keyway position, through an interlock rather than an inspection.

If this cell ran its inspection plan, sample sizes and limits from an MES, SI 24 would allow the plan to carry summary information with a direct reference to the MES record in place of the detailed columns.

Pre-submission self-check

Before the plan goes into the PPAP package, walk it against the requirements cited above:

  • The phase (prototype, pre-launch or production) is marked, and any pre-launch plan reflects the Safe Launch controls the customer expects.

  • The part number, or a common control plan designation for a family, covers exactly the parts being submitted.

  • Every special characteristic on the drawing appears with the customer's symbol and a stated monitoring method.

  • Job set-up verification and first-off/last-off checks are present for each operation where they apply.

  • Process characteristics that drive the critical features are controlled, not only the features themselves.

  • Every gauge named has an MSA study to back it in element 8.

  • Every reaction plan states the process action, containment scope and product disposition, and names a responsible role.

  • Operation names, numbering and revision levels agree across the process flow, PFMEA and control plan.

  • For automated processes using SI 24, the summary plan points to a specific, revision-controlled system record.

  • Customer-specific requirements (element 17) have been read for any control plan format, approval or content rules.

Keeping the plan live after approval

Approval at PPAP is the start of the document's working life. The review triggers in the IATF summaries are the events plants most want to avoid: a nonconforming shipment, a customer complaint that drives corrective action, a process change. Each one should send someone back to the control plan to ask whether the control that failed was missing, too infrequent or not followed, and some of the resulting revisions will need customer approval. A plant that treats the plan this way tends to find its weaknesses through its own reviews rather than through an escape or an audit finding.

Sources

Share

Frequently asked questions

What is a control plan in PPAP?

It is the supplier's written plan for controlling a part's production process, listing for each step the characteristics, specification, measurement method, sample size and frequency, control method and reaction plan. It is element 7 of the 18 PPAP elements and is reviewed and signed off by supplier and customer.

What is the difference between a PFMEA and a control plan?

The PFMEA analyses what could go wrong at each process step, why, and which prevention and detection controls exist. The control plan commits those controls to the floor, stating how each characteristic is checked, how often, and what happens when a check fails.

What changed with the AIAG Control Plan 1st Edition?

In March 2024 AIAG released a standalone Control Plan 1st Edition (CP-1), replacing guidance in the 1995 APQP and Control Plan manual. It adds a Safe Launch requirement to the control plan phases, guidance for highly automated processes and control plan software, family control plans, and a Responsible Person column on the form.

Do existing control plans have to be rewritten for the 2024 AIAG manual?

DQS reported before publication that suppliers would not have to update existing control plans to meet the new requirements. AIAG said GM would require the new editions from 1 September 2024.

Can a machining process use a summary control plan?

Yes. DQS reports that IATF Sanctioned Interpretation 24, effective June 2022, allows highly automated processes including machining to use summary control information with direct references or linkage to a system such as an MES that holds the tolerances, sample sizes and frequencies.